110 Acme Packet 6100 Hardware Installation and Maintenance Guide
DC Power Supply
Physical
Dimensions
This table lists the physical dimensions and weight of the Acme Packet 6100
DC power supply.
Table 7 - 20. Acme Packet 6100 DC Power Supply Physical Dimensions
Specification Description
Height 1.575” (4.00 cm)
Width 2.146” (5.45 cm)
Depth 13.26” (33.68 cm)
Weight 2lbs., 5 oz. (1.05 kg)
Important: This equipment is intended for installation in Network
Telecommunication Facilities.
Fan Module
Specifications
This table lists the fan module specifications for the Acme Packet 6100.
Table 7 - 21. Acme Packet 6100 Fan Module Specifications
Specification Description
Number of Fans 5
Total Maximum Airflow 100 CFM
Electrical Specifications
Refer to the following tables for information regarding the electrical
specifications of the Acme Packet 6100.
Power Supply
Input Circuit Fuse
Requirements
This table lists the input circuit fuse and cable size requirements for the Acme
Packet 6100.
Table 7 - 22. Acme Packet 6100 Power Supply Input Circuit Fuse Requirements
Power Circuit Fuse Rating Power cable size
120 VAC 15 AMP 18 AWG
240 VAC 10 AMP 18 AWG
-48 VDC 30 AMP 12 AWG
Alarm Port Dry
Contact Current
Limits
This table lists the alarm port electrical characteristics of the Acme Packet 6100.
Table 7 - 23. Acme Packet 6100 Alarm Port Dry Contact Current Limits
Specification Value
Max AC switching current 0.3 A @ 125 VAC
Max DC switching current 1 A @ 30 VDC