INSTRUCTION & MAINTENANCE
MANUAL
WSB 5100 Controller
L-R SYSTEMS, INC.
624 ANDERSON DR.
ROMEOVILLE, IL 60446
PHONE 815-372-1600
FAX 815-372-1601
WWW.L
-
RSYSTEMS.COM
Vue de la page 0
1 2 3 4 5 6 ... 31 32

Résumé du contenu

Page 1 - WSB 5100 Controller

INSTRUCTION & MAINTENANCE MANUAL WSB 5100 Controller L-R SYSTEMS, INC. 624 ANDERSON DR. ROMEOVILLE, IL 60446 PHONE 815-372-1600 FAX 815-37

Page 2 - CONGRATULATIONS!

10 RECIPE by Ratio From the Main screen press RECIPE to go to the recipe screen Fig. 7 To create or edit recipe: - Press on dark blue area at

Page 3

11 The RUN Screen From The Main screen press RUN to go to the Run screen Fig. 7 To start blender: - Press on dark blue area at RECIPE. Th

Page 4

12 Manual EMPTY MATERIALS From the Main screen press EMPTY MATERIALS to go to this screen Fig. 9 You can empty each component by pressing dark

Page 5

13 ALARMS From the Main screen press ALARM to go to this screen Fig. 11 You can clear alarms by pressing ALARM CLEAR. To see the next page(

Page 6

14 MAXIMUM TARE WEIGHT EXCEEDED ALARM: TOO MUCH BLENDER VIBRATION ALARM: BAD FEEDER /

Page 7 - CONTROLS

15 DIAGNOSTICS From the Main screen press SYSTEM to go to Diagnostic screens. Fig. 12 From this screen you can see the status of each input and o

Page 8 - RECIPE by weight

16 SET-UP Enter the existing load cell size. Enter weigh chamber size calculated from CUBIC/FT X 35lb. Set the mixer timer from 0 to 60 sec per

Page 9 - RECIPE by percent

17 PASSWORD Instructions for using the Password feature with the 5200 controller. #1 is the PASSWORD screen. This screen has 3 items: Password

Page 10 - RECIPE by Ratio

18 MAINTENANCE CALIBRATION Calibration Function 1. The initial WC (initial weight on load cell) reading is an arbitrary value. 2. Press SET TA

Page 11 - The RUN Screen

19 NOTES: 1- The above information will be sent out the serial RS232 port, if you are at the Top Level RUN Mode Menu and you press the

Page 12 - Manual TOTALS

2 CONGRATULATIONS! You have purchased one of the finest Gravimetric Weigh Blenders on the market today. Your Blender SN: ______________

Page 13 - BIN x LOW LEVEL ALARM:

20 COMMUNICATION PROTOCOL Weigh Scale Blender Controller REMOTE RS422 POLLING FOR INFORMATION Information Request Data Packet: (Control

Page 14 - FIX Then Press RUN

21 SELF CLEANING BLENDER BIN OPTION 1. Turn OFF station on vacuum loader. 2. Remove material through drain tube on bin and run BIN EMPTY MODE

Page 15 - DIAGNOSTICS

22 ELECTRIC MOTOR INFORMATION SAFETY: The use of electric motors and generators, like that of all other utilization of concentrated power, is p

Page 16

23 Before Starting 1. Before attempting to start, check all connections and fuses. 2. Proper consideration should be given to rotating members:

Page 17

24 Service Instructions Syntron Light-Capacity Electromagnetic Vibrating Feeders Models: F-T01-A and DF-T01-A Contents Page Introduction

Page 18

25 THEORY OF OPERATION Model F/DF-T01-A Feeder operation produces a vibrating stroke on the surface of the feeder trough. The stroke is obtained b

Page 19

26 LONG TERM STORAGE When received, the equipment should be carefully unpacked. Give the equipment a thorough visual inspection to reveal any damag

Page 20

27 OPERATION CAUTION: Unauthorized modification of the feeder or use of unauthorized replacement parts may damage the feeder. L-R Systems will no

Page 21 - REMOVABLE BINS

28 CAUTION: Any signs of excessive heat or burned components are an indication of trouble. At first notice of an overheating condition, immediately

Page 22 - ELECTRIC MOTOR INFORMATION

29 SPRING REPLACEMENT Replacement springs must be of the same size and thickness as those removed. L-R Systems recommends replacing all springs ra

Page 23

3 INDEX Page 1 Introduction 2 Index 3 Installation Instructions 4 WSB 100 5 WSB 1000 - 8000 6 Controls – Main Screen 7 C

Page 24

30 CHECKING FEEDER CURRENT When using an analog clamp on meter to read the current of the feeder, the meter reading must always be multiplied by a

Page 25

31 PARTS LIST – VIBRATING FEEDER MODELS: F-T01-A and DF-T01-A ITEM DESCRIPTION QUANTITY PART NO. A Armature 1 A-81697-A Armature

Page 26

NOTICE REGARDING DAMAGE & RETURNS This merchandise left our plant in first class condition and may Not be returned fo

Page 27

4 INSTALLATION INSTRUCTIONS - Put the blender in place and anchor it down to the floor (if blender consists of several frames set the bottom an

Page 28

5 100 100 100 100 –––– 1000 lbs/hr 1000 lbs/hr 1000 lbs/hr 1000 lbs/hr MODEL WSB 100

Page 30

7 CONTROLS The opening splash screen. Fig. 1 Main screen Fig. 2 - The various Status states are as follows: Stopped, Running, Ini

Page 31 - Service Manual SM0751-083002

8 RECIPE by weight From the Main screen press RECIPE to go to the recipe screen Fig. 3 To create or edit recipe: - Press on dark blue are

Page 32 - L-R SYSTEMS

9 RECIPE by percent From the Main screen press RECIPE to go to the recipe screen Fig. 5 To create or edit recipe: - Press on dark blue area at

Commentaires sur ces manuels

Pas de commentaire